PCS_cmyk
PCS Diagram A3

v-Lab Key Points

      • Centralised Database
      • Browser Based System including tablet (Android and iPAD)
      • Comprehensive Security System including
        • Operator Management
        • Roles (Groups)
      • Instrument Interfacing, non vendor specific
        • ASTM, POCT1A-2, HL7, Propriety protocols
        • Bi-directional capabilities
        • Instrument management such as activation dates for connected instruments
      • Interfaces to LIMS / PAS for ADT feed / eMR’s / HMS via HL7
      • On-Line Training and Competency Testing Module (Integrated)
        • Used for Certification of Operators
      • Document Management System (Integrated)
        • Manage all documents from a central database
        • Version controlled documentation
      • Incident Management Module (Integrated)
        • Integrated into personal Diary and ‘To Do List’
      • Stock Management Module (Integrated)
      • Asset Management Module (Integrated)
      • Integrated Rules Wizard
        • Customised rules to suit your business process
      • Reporting
        • Integrated Reporting Tool (SQL). Open ODBC database
        • Ability to create own customised reports / graphs
        • Reports can be printed / e-mailed / faxed / saved to file
        • Report output in different formats: HTML, PDF, RTF, XLS, CSV, TXT
      • QAP results
        • Records QA data separately from QC and Patient results
        • Interface capability to QA programs such as RCPA
        • Ability to automatically e-mail QAP results to appropriate person(s)
      • QC results
        • Manual QC and QA entry screen for non-connectivity instruments
        • QC results are displayed in different colours representing a visual Levy-Jennings plot
          E.g. Results within 1 SD = Green, within 2SD = light Green, within 3SD = Orange and outside 3SD = RED
        • Westgard rules display the pass/warning/failure of the QC results in different colours
          E.g. The display has been colour coded. A ‘Pass’ = Green, the ‘Westgard warnings’ = Orange and the ‘Failures’ = Red
        • Levy-Jennings graphs
        • Records reagent name, reagent lot number, reagent expiry date, operator who performed test, analyser, location of analyser, date and time of test, Name/Level/Lot number / Expiry Date of QC
        • Displays each results running mean / SD / CV and Westgard rule
        • Has QC result validation / rejection capability
      • Patient results
        • Displays patient result / normal range / patient’s average result  - per test of the selected patient
        • Displays QC test results done before and after selected patient result
        • Displays QA test done before and after selected patient result
        • Records reagent name, reagent lot number, reagent expiry date, operator who performed test, analyser, location of analyser date and time of test
        • Records all comments – Result comment and Episode/Patient comment
        • Fully functional Result Enquiry
      • Operator Data
        • Includes dates of Certification / Re-certification
        • E-mail Alerts for re-certification
        • Uploading of Operators to instruments - e.g. only certified operators to be loaded
      • Optional extras
        • Billing Module
        • Financial Module
        • Anti Coagulation Management Module